you’re in the right place. Praque assists in the design, engineering, and manufacturing of your specific damper application.
– Damping direction: Clockwise (CW)
– Outer diameter : 20 mm
– Maximum Length: 62 mm
– Maximum angle: 115°
– Operating temp: -5 ~ 50°C
– Housing & shaft material: PA6 30%GF
– Fluid Type: Silicone
– Torque Value:- 15 ~ 25 kgf.cm
Working function of Damper vary according to ambient temperature. Damping properties decreases when temperature increase and vice-versa. The reason is Viscosity of oil used vary according to temperature. Damper performance return back to normal when temperature backs to normal. The right side graphs is showing estimation of lid faster closer with temperature rise..
Test Items |
Test Condition |
Specification |
---|---|---|
Free Fall Test (Normal Condition)
|
05 Cycles
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
Force Close Test
|
10,000 Cycles
|
Closing time ≥ 2 Seconds
|
Free Fall Tet
|
50,000 Cycles
|
Closing time ≥ 2 Seconds
|
Warehouse Test
|
Keeping in WH for 4 days
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
– Damping direction: Counter Clockwise (CCW)
– Outer diameter : 20 mm
– Maximum Length: 62 mm
– Maximum angle: 115°
– Operating temp: -5 ~ 50°C
– Housing & shaft material: PA6 30%GF
– Fluid Type: Silicone
– Torque Value:- 15 ~ 25 kgf.cm
Working function of Damper vary according to ambient temperature. Damping properties decreases when temperature increase and vice-versa. The reason is Viscosity of oil used vary according to temperature. Damper performance return back to normal when temperature backs to normal. The right side graphs is showing estimation of lid faster closer with temperature rise..
Test Items |
Test Condition |
Specification |
---|---|---|
Free Fall Test (Normal Condition)
|
05 Cycles
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
Force Close Test
|
10,000 Cycles
|
Closing time ≥ 2 Seconds
|
Free Fall Tet
|
50,000 Cycles
|
Closing time ≥ 2 Seconds
|
Warehouse Test
|
Keeping in WH for 4 days
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
– Damping direction: Clockwise (CW)
– Outer diameter : 20 mm
– Maximum Length: 62 mm
– Maximum angle: 115°
– Operating temp: -5 ~ 50°C
– Housing & shaft material: POM
– Fluid Type: Silicone
– Torque Value:- 15 ~ 25 kgf.cm
Working function of Damper vary according to ambient temperature. Damping properties decreases when temperature increase and vice-versa. The reason is Viscosity of oil used vary according to temperature. Damper performance return back to normal when temperature backs to normal. The right side graphs is showing estimation of lid faster closer with temperature rise..
Test Items |
Test Condition |
Specification |
---|---|---|
Free Fall Test (Normal Condition)
|
05 Cycles
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
Force Close Test
|
10,000 Cycles
|
Closing time ≥ 2 Seconds
|
Free Fall Tet
|
50,000 Cycles
|
Closing time ≥ 2 Seconds
|
Warehouse Test
|
Keeping in WH for 4 days
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
– Damping direction: Counter-clockwise (CCW)
– Outer diameter : 20 mm
– Maximum Length: 62 mm
– Maximum angle: 115°
– Operating temp: -5 ~ 50°C
– Housing & shaft material: POM
– Fluid Type: Silicone
– Torque Value:- 15 ~ 25 kgf.cm
Working function of Damper vary according to ambient temperature. Damping properties decreases when temperature increase and vice-versa. The reason is Viscosity of oil used vary according to temperature. Damper performance return back to normal when temperature backs to normal. The right side graphs is showing estimation of lid faster closer with temperature rise..
Test Items |
Test Condition |
Specification |
---|---|---|
Free Fall Test (Normal Condition)
|
05 Cycles
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
Force Close Test
|
10,000 Cycles
|
Closing time ≥ 2 Seconds
|
Free Fall Tet
|
50,000 Cycles
|
Closing time ≥ 2 Seconds
|
Warehouse Test
|
Keeping in WH for 4 days
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
Working function of Damper vary according to ambient temperature. Damping properties decreases when temperature increase and vice-versa. The reason is Viscosity of oil used vary according to temperature. Damper performance return back to normal when temperature backs to normal. The right side graphs is showing estimation of lid faster closer with temperature rise..
Test Items |
Test Condition |
Specification |
---|---|---|
Free Fall Test (Normal Condition)
|
05 Cycles
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
Force Close Test
|
10,000 Cycles
|
Closing time ≥ 2 Seconds
|
Free Fall Tet
|
50,000 Cycles
|
Closing time ≥ 2 Seconds
|
Warehouse Test
|
Keeping in WH for 4 days
|
Closing Time = 10 ~ 25 seconds (As per customer requirements)
|
Factory Address- 25/1/1, Village Kankrolla, Gurgaon, Haryana 1220505, India
Registered Address- 1807B/31, Street No. 4, Shastri Colony Sonipat, Haryana 131001, India
©2022 Praque Industries Pvt. Ltd. Copyright. All Right Reserved. Designed by Falcon Technosoft